Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Rev. Col. Bras. Cir ; 42(1): 37-42, Jan-Feb/2015. graf
Article in English | LILACS | ID: lil-746245

ABSTRACT

OBJECTIVE: To evaluate the efficacy of endovascular repair of popliteal artery aneurysms on maintaining patency of the stent in the short and medium term. METHODS: this was a retrospective, descriptive and analytical study, conducted at the Integrated Vascular Surgery Service at the Hospital da Beneficência Portuguesa de São Paulo. We followed-up 15 patients with popliteal aneurysm, totaling 18 limbs, treated with stent from May 2008 to December 2012. RESULTS: the mean follow-up was 14.8 months. During this period, 61.1% of the stents were patent. The average aneurysm diameter was 2.5cm, ranging from 1.1 to 4.5cm. The average length was 5cm, ranging from 1.5 to 10 cm. In eight cases (47.1%), the lesion crossed the joint line, and in four of these occlusion of the prosthesis occurred. In 66.7% of cases, treatment was elective and only 33.3% were symptomatic patients treated on an emergency basis. The stents used were Viabahn (Gore) in 12 cases (66.7%), Fluency (Bard) in three cases (16.7%), Multilayer (Cardiatis) in two cases (11.1%) and Hemobahn (Gore) in one case (5.6%). In three cases, there was early occlusion (16.6%). During follow-up, 88.2% of patients maintained antiplatelet therapy. There was no leakage at ultrasound (endoleak). No fracture was observed in the stents. CONCLUSION: the results of this study are similar to other published series. Probably, with the development of new devices that support the mechanical characteristics found on the thighs, there will be improved performance and prognosis of endovascular restoration.


OBJETIVO: Avaliar a eficácia da correção endovascular do aneurisma de artéria poplítea quanto à manutenção da perviedade da endoprótese, em curto e médio prazo. MÉTODOS: trata-se de estudo retrospectivo, descritivo e analítico, realizado no Serviço de Cirurgia Vascular Integrada do Hospital Beneficência Portuguesa de São Paulo. Foram acompanhados 15 pacientes com aneurisma de poplítea totalizando 18 membros tratados com endoprótese, no período de maio de 2008 a dezembro 2012. RESULTADOS: o tempo médio de seguimento foi 14,8 meses. Nesse período, 61,1% das endopróteses estavam pérvias. A média de diâmetro dos aneurismas foi 2,5cm, variando de 1,1 a 4,5cm. A extensão média encontrada foi 5cm, variando de 1,5 a 10cm. Em oito casos (47,1%), a lesão cruzava a linha articular e, em quatro destes, ocorreu oclusão da prótese. Em 66,7% dos casos, o tratamento foi eletivo e apenas 33,3% eram pacientes sintomáticos, tratados em caráter de urgência. As endopróteses usadas foram a Viabahn (Gore) em 12 casos (66,7%), Fluency (Bard) em três casos (16,7%), Multilayer (Cardiatis) em dois casos (11,1%) e Hemobahn (Gore) em apenas um caso (5,6%). Em três casos, ocorreu oclusão precoce (16,6%). Durante o seguimento, 88,2% dos pacientes mantiveram a antiagregação plaquetária. No seguimento ultrassonográfico não foi observado nenhum vazamento (endoleak). Não foi verificada nenhuma fratura nos Stents. CONCLUSÃO: Os resultados obtidos nesse estudo são semelhantes aos de outras séries publicadas. Provavelmente com o desenvolvimento de novos dispositivos que suportem as particularidades mecânicas encontradas na região poplítea, haverá como melhorar o desempenho e prognóstico da restauração endovascular.


Subject(s)
Humans , Aneurysm , Endovascular Procedures , Peripheral Vascular Diseases , Popliteal Artery
2.
J. vasc. bras ; 13(2): 88-93, Apr-Jun/2014. tab, graf
Article in English | LILACS | ID: lil-720884

ABSTRACT

CONTEXT: Anticoagulation with warfarin is considered the appropriate treatment for venous thromboembolism and other thrombotic pathologies. Regular INR control is required for dosage adjustment and therapeutic control. Use of portable monitoring systems optimizes management of these patients. OBJECTIVE: To compare INR measurements taken using the portable Coaguchek XS system in capillary blood with the standard laboratory method using venous blood. METHOD: Fifty-two samples each of venous and capillary blood were collected from nineteen patients on warfarin, who had been admitted to the Hospital da Beneficência Portuguesa de São Paulo, and analyzed using the conventional method and the Coaguchek XS system, respectively. RESULTS: Spearman's correlation coefficient ® for the overall performance of the two methods was 0.978 (p<0.0001; 95%CI 0.961-0.988). The Kappa measure of agreement for all patients was 76.8% (p<0.001; IC: 95% 0.975-0.561). Mean INR according to the Coaguchek XS system underestimated the values provided by the conventional method by -0.01 INR points, with a standard error of 0.342. Results for INR values greater than 3.5 were satisfactory with a correlation coefficient of 0.71, but without statistical significance (p>0.714). CONCLUSIONS: The Coaguchek XS system can be used to monitor prothrombin time in patients on oral anticoagulants, provided INR values greater than 3.5 are confirmed using the conventional laboratory method...


CONTEXTO: Anticoagulação por varfarina (warfarin) é considerada tratamento adequado para tromboembolismo venoso e outras patologias trombóticas. Deve ser realizada a mensuração do Índice Internacional Normalizado (INR) para ajuste de dosagem de medicamento para manutenção dos pacientes na faixa terapêutica. O uso de dispositivos portáteis otimiza o controle desses pacientes. OBJETIVO: Comparar as medidas do INR realizadas pelo sistema portátil Coaguchek XS, em sangue capilar, com o método laboratorial padrão em sangue venoso. MÉTODO: Dezenove pacientes em uso de varfarina, internados no Hospital da Beneficência Portuguesa de São Paulo, foram submetidos à coleta de 52 amostras analisadas pelo método convencional e coleta de sangue capilar para medida com o sistema Coaguchek XS. RESULTADOS: O coeficiente de correlação (r) de Spearman por meio da comparação de desempenho global entre os dois métodos foi de 0,978 (p<0,0001; IC: 95% 0,961-0,988). O percentual de concordância Kappa para todas as faixas foi de 76,8% (p<0,001; IC: 95% 0,975-0,561). O INR médio do sistema Coaguchek XS subestimou os valores obtidos em -0,01 pontos de INR, quando comparado ao método convencional, com erro padrão de 0,342. Valores acima de 3,5 mostraram resultados satisfatórios com coeficiente de correlação de 0,71, mas sem significância estatística (p>0,714). CONCLUSÕES: O sistema Coaguchek XS pode ser utilizado na monitorização do tempo de protrombina em pacientes com uso de anticoagulantes orais, desde que valores de INR acima de 3,5 sejam confirmados por meio de medidas realizadas em laboratório convencional...


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Blood Coagulation , Equipment and Supplies/economics , Venous Thromboembolism/therapy , Cross-Sectional Studies , Prothrombin Time/adverse effects , Warfarin/administration & dosage
SELECTION OF CITATIONS
SEARCH DETAIL